Sign In | Join Free | My carsrow.com
China ZHEJIANG XINCHOR TECHNOLOGY CO., LTD. logo
ZHEJIANG XINCHOR TECHNOLOGY CO., LTD.
XINCHOR TECHNOLOGY CO., LTD. Manufacturer of Structural Strengthening Products Since 2000.
Site Member

6 Years

Home > Chemical Anchor Adhesive >

Anti Corrosion Thixotropic Epoxy Concrete Fasteners Alkali Resistant

ZHEJIANG XINCHOR TECHNOLOGY CO., LTD.
Contact Now

Anti Corrosion Thixotropic Epoxy Concrete Fasteners Alkali Resistant

Brand Name : XINCHOR

Model Number : FixingChor 165

Place of Origin : China

MOQ : 100pcs

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 100,000pcs per month

Delivery Time : 30 days

Packaging Details : individual in plastic cartridges, 20pcs/ctn,

Tensile Strength : 55KN

Mix ratio : 1:1

Resin type : Modified Pure Epoxy

Application : structural strengthening

T-peeling strengt : less than 25mm

Tensile Shear Strength : above 10Mpa

Capacity : 650ml

Rebar size : Dia. 10-32

Contact Now

Anti Corrosion Epoxy Concrete Fasteners Weather Proof Good Thixotropy Alkali Resistant

650ml 1:1 Two Components Chemcial Anchor Adhesive For Structural Strengthening
Chemical anchor adhesive, epoxy injection mortar, Chemical fixing glue,
Chemical anchoring system used for anchoring and rebar connections in concrete.

Item #: FixingChor142
Capacity: 420ml
Materials: Epoxy
Mixing Ratio: 2:1

ATTENTION

-Do not install anchors when substrate temperature is less than 0°C.

-Do not install anchors when the temperature is less than 10°C.

-At temperatures below 10°C should be warmed or stored in temperatures

of 10-30°C for 24hours prior to use to improve product flow and cure.

-If the gelling time expires, please use a new static mixer.

-Do not cut or shorten nozzles.

-If the cartridge is not finished, please clean the opening, then put the plug back and cap tightly.

-It can be used again in the future by replacing the static mixer.

-Please ensure hole is properly cleaned. Hole may be damp but must be free from water.

-Do not dilute mortar with any solvents and/or other chemicals.

-Not suitable for use in diamond cored holes without roughening.

-Please ensure spiral mixer in nozzles.

-Do not install into uncured concrete.

-Please use Xinchor nozzles, other nozzles may cause ineffective mixing

and reduce the properties of the mortar.

Ultimate-performance injectable hybrid mortar with approvals for rebar connections and heavy-duty anchoring

Base materials: Concrete (cracked), Concrete (uncracked), Masonry (grout-filled CMU)

Base material condition: Dry, Wet

Features

No hole cleaning required with metal anchor rod

Automatic hole cleaning with drill bits in combination with Hilti vacuum cleaners

Fulfills the requirements of the most demanding ICC-ES and ETA C2 approvals for seismic applications

Working time optimized for anchor applications

Suitable for use in cracked and uncracked concrete with all anchor rods and rebar

Testing project

Condition

Index

Gel Performance (According to China National Standard GB50728-2011)

Splitting Tensile Strength (MPa)

Under (23±2)℃,(50±5)%RH, tested by loading speed of 2mm/min

≥8.5

Flexural Strength (MPa)

≥50

(no fragment damage)

Compressive Strength (MPa)

≥60

Bonding Capacity (According to China National Standard GB50728-2011)

Steel-Steel Tensile Shear Strength (MPa)

(23±2),(50±5)%RH

≥10

Bonding strength of Ribbed steel bar (or screw) with concrete under constrain drawing condition

(23±2)(50±5)%RH

C30,Ф25,L=150mm

≥11

C60,Ф25,L=150mm

≥17

Steel-Steel T-peeling strength (mm)

(23±2)℃,(50±5)%RH

≤25

Non-volatile content

(105±2)℃,(180±5)min

≥99%

Ageing resistance to heat and humidity 90d

Reduction rate of tensile strength

Under normal room temperature

≤12%

(According to China National Standard JGJ145-2013)

Tensile Strength (after high temperature welding)

Dia12 Grade II steel, C30 concrete

Hole dia.16mm, Depth: 150mm

55.1N, 57.0N, 54.8N

Approved for anchorings in

Railway or express way modification works

Structure reinforcement

Curtain wall installing

Concrete, cracked and non-cracked Applications

Rebar planting in concrete structures.

Bridge modification works

Keel fixing in out wall

ATTENTION

- Do not install anchors when the temperature is less than 10°C.

- If the cartridge is not finished, please clean the opening, then put the plug back and cap tightly.

- At temperatures below 10°C should be warmed or stored in temperatures

of 10-30°C for 24hours prior to use to improve product flow and cure.

- If the gelling time expires, please use a new static mixer.

- Do not cut or shorten nozzles.

- It can be used again in the future by replacing the static mixer.

- Please ensure hole is properly cleaned. Hole may be damp but must be free from water.

- Do not install anchors when substrate temperature is less than 0°C.

Anti Corrosion Thixotropic Epoxy Concrete Fasteners Alkali Resistant


Product Tags:

Anti Corrosion Epoxy Concrete Fasteners

      

Alkali Resistant Epoxy Concrete Fasteners

      

Thixotropic Epoxy Resin Anchors

      
 Anti Corrosion Thixotropic Epoxy Concrete Fasteners Alkali Resistant Manufactures

Anti Corrosion Thixotropic Epoxy Concrete Fasteners Alkali Resistant Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ZHEJIANG XINCHOR TECHNOLOGY CO., LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)